Society is dependent on the flow of electricity and the flow information for everything from commerce to communications… |
||||||||||||
|
|
||||||||||||
|
|
|
|||||||||||
POWER |
RACK |
AIR |
FLOORING |
|||||||||
|
FIRE |
CONTROL |
MONITORING |
SERVICES |
|||||||||
|
q FM-200 |
q KVM |
|||||||||||
Uninterruptible Power Supply |
||||||||||||
|
Uninterruptible Power Supply (UPS) provides the backup power protection required for 24/7 operation. Formare has installed UPS systems from the most basic single-phase units in communication closets to sophisticated, scalable, redundant, 3-phase, installations in large internet data centers. |
||||||||||||
|
UPS systems provide
continuous battery up time for IT and communications equipment through
relatively short power outages and provide ride-through support for transfer
to backup generators for long-term outages. |
|
|||||||||||
Power Distribution & Conditioning |
||||||||||||
|
Effective power
distribution is key to a highly available |
||||||||||||
Generator Backup |
||||||||||||
|
The nature of today’s
24/7 business environments requires a continuous and reliable power
supply. An emergency Backup Generator can provide you with a secondary
power source when the primary power is interrupted. Backup Generators
can be fully automatic systems, which monitor the incoming electricity and
provide an extended secondary power source on loss of primary power. |
||||||||||||
|
|
||||||||||||
Battery & Flywheel Energy Storage Systems |
||||||||||||
|
|
||||||||||||
|
|
||||||||||||
Enclosures & Open Frame Racks |
||||||||||||
|
Formare offers the next generation, high quality, enclosure
solutions designed to meet the needs of today and tomorrow's networking
environment by offering deeper enclosures, superior ventilation, a robust
offering of enclosure sizes and options and enclosure solutions that are easy
to use and install. |
|
|||||||||||
Power & Data Cabling |
||||||||||||
|
Proper coordination of
power & data cabling are necessary for serviceability and the ability to
adapt to ever changing requirement. |
||||||||||||
|
Formare employs various strategies from under floor, to overhead cable ladder, to rack based trough installed cable management schemes depending on the situation. |
||||||||||||
|
|
||||||||||||
Precision Air Conditioning |
||||||||||||
|
IT environment equipment
requires rigid environmental conditions for reliable operation. Precision
air conditioning systems and rack-based air handling systems are specifically
designed for the |
||||||||||||
Rack-Based Air Handling |
||||||||||||
|
Today’s high-density loads provide a unique situation where the ability to provide increased power for a given load is curtailed only by the data center environments ability to remove the heat from that load. |
||||||||||||
|
|
These systems connect into the raised floor and pulls supply air directly into the enclosure thereby preventing the conditioned air from mixing with warmer room air before reaching the equipment. |
|||||||||||
|
The
rack air distribution unit helps to eliminate temperature differences between
the top and bottom of the enclosure. It also prevents hot exhaust air from recirculating to the inlet of the enclosure.
|
||||||||||||
Access Floor Air Distribution |
||||||||||||
|
An access floor is
actually a floor raised above a floor. Its purpose is to create a controlled
area for wire management and air distribution. |
||||||||||||
|
|
||||||||||||
Sub-Floor Cabling & Water Detection |
||||||||||||
|
Moisture below the floor
can damage wiring or equipment and cause costly downtime. A sub-floor
water detection system can provide immediate warning. Alarming can be
provided via various audible, visual, in-band and out-of-band methods. |
||||||||||||
|
|
||||||||||||
Fire Suppression & Detection |
||||||||||||
|
Fire protection &
detection is an absolute necessity for your business’ survival. In the
event of a fire, heat and smoke can, at best, only damage delicate electronic
equipment and, worse, take out the building. A fire protection strategy
has two parts, an FM-200 system that protects the data center equipment and a
‘wet’ or ‘pre-action’ sprinkler system that is used to save the building. Formare evaluates code & insurance
requirement in determining the best technique for a given project. |
||||||||||||
|
|
||||||||||||
Remote Access & Control |
||||||||||||
|
Whatever
the size and complexity of your IT infrastructure and regardless of platform,
types of connections or existing equipment, Formare
can build the right solution for access and control of your servers and other
IT devices – anytime you need it, from anywhere. |
||||||||||||
|
|
||||||||||||
Network Operations Centers (NOC) |
||||||||||||
|
The
network operations center (NOC) or command bridge can be as simple as a
single desk with a single user access point or as complex as a multi-user
production and/or monitoring console. In either case, Formare can provide solutions to meet the
access needs of the environment. |
||||||||||||
|
A NOC production
console is a dedicated location from which multiple user can initiate network
activities and tasks on network assets that may be spread throughout the
enterprise. |
||||||||||||
|
Conversely,
a NOC monitoring console serves as a central monitoring locale for evaluating
the present state of the network and as a logging point for all alarm
conditions. |
|
|||||||||||
|
|
||||||||||||
In-Band & Out-of-Band Monitoring |
||||||||||||
|
In-band monitoring refers
to accessibility of systems status via the existing network infrastructure.
Out-of-band monitoring refers to the ability to access and/or remotely
control systems independent of the existing network infrastructure.
Out-of-band access can be accomplished via a separate data network or
‘dial-in’ capability of individual pieces of equipment. q Power q
UPS q
Generator q
Temperature & Humidity q
Leak detection q
Intrusion
|
||||||||||||
|
|
||||||||||||
Planning & Design Consulting |
||||||||||||
|
Facility and network
infrastructure is the life-blood of the organization. The goal of Formare's data center design consulting is to deliver
manageable, scalable and highly available environments for mission critical
data networks. Our methodology combines the business and technology expertise
needed to ensure customer satisfaction from concept through completion. |
||||||||||||
Construction |
||||||||||||
|
The
construction and/or expansion of a data center must be done right the first
time. Formare’s years of
experience will guide you through the tedious tasks of computer room design
and construction. If you are expanding, Formare
will make sure that your existing computer room remains clean and operational
during all phases of construction and startup. |
||||||||||||
|
If
needed, Formare will work along side
your fit-out contractor to assure that your data center is done in a timely
and effective manner. |
|
|||||||||||
Site Cleaning |
||||||||||||
|
It is imperative to keep
the data center environment clean of any dust and dirt because of the harm
that can be done to the operating systems. Therefore, after data center
construction is complete, we thoroughly clean above and below the raised
floor with particular attention to detail. In addition to post
construction cleaning, regular cleanings are highly recommended throughout
the life of the data center. Our experienced cleaning crews are well
aware of the caution that must be employed in an active data center
environment during the regular cleanings. q
Encapsulation of sub floor to eliminate concrete
powdering q
Systematic vacuuming to remove dirt, dust and
contaminants q
Antistatic cleaning and machine scrubbing of high
pressure laminate raised floor surfaces q
Damp wiping of environmental equipment and counter
surfaces q
Carpet cleaning q Ramp and tile floor landing waxing |
||||||||||||
|
|
||||||||||||
Maintenance |
||||||||||||
|
When construction of the
data center is complete, Formare offers
a preventive maintenance service agreement to ensure reliable operation of
the critical systems installed. Since we designed and built your
facility, we have a thorough understanding of these systems. Therefore, our
management and field technicians are in the best position to provide superior
service. q
Develop an annual preventive maintenance schedule q
Coordination and tracking of all service visits q
Physical site inspecting q
Review of invoices for additional services q
Review of all service reports q
Resolution of service issues q
Data center cleaning q
Air conditioning equipment q
Rack-based air handling equipment q
Building HVAC q
UPS & batteries q
Static switching equipment q
Free standing & rack-based power distribution
equipment q
Power & data cable physical inspection q
Infrared power connection scanning q
Generator and automatic transfer switch equipment q
Fire suppression & detection equipment q
Sprinkler systems Coordination
& communications can be accomplished via ‘paper trail’ and/or an online
portal.
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||